The following points should be noted in the use of intelligent charging rack for mine lamps:
1. The charging cabinet shall be strictly inspected for any damage or looseness of the components in transit before being used with electricity.
2. The charging cabinet is connected with a 220V alternating current, so charged maintenance is strictly prohibited. Non-professional maintenance personnel is strictly prohibited to remove the side panels to avoid electric shock hazard.
Software system function of intelligent mine lamp rack
1.Intuitive and clear interface
Our software interface uses icons to display the status of the mine lamp, which is more intuitive with better visual effect. However, that of Shijiazhuang City uses character to display, which is rigid and not humanized
2. Prompt automatic report generation
Note for charging of mine lamp charging cabinet
1. In the charging process, as the charging voltage is higher than the rated voltage of the bulb, making the bulb easy to be burned out, the lamp head switch should be turned off. So that the lamp is off when charging.
2. In the initial charging process, after 24 hours of charging, the charging indicator needle of each battery should be in the same position as the indicator of the indicator, at about 1 ampere. In case the needles of individual charging indicators are not moving or are too far apart, the respective exposures should be checked.